Wiring Services
Cable and Wiring

TNS designs, installs, maintains, and modifies inter-building and intra-building cable/wiring networks for all University-owned and select University affiliated properties. Cable/wiring projects tend to fall into one of four categories:

  1. TNS infrastructure upgrades where the expense is paid through central funds
  2. New construction and renovations where the expense is charged to a particular project budget
  3. Occupant requested upgrades initiated by an administrative or academic unit with the expenses charged to a departmental budget. Depending on the nature of the request, both installation and recurring charges may be applicable.
  4. Private fiber installations and use. Use of University fiber is considered "private" if the use of the fiber creates a dedicated point-to-point link between separate buildings to create a private network.

TNS System Maintenance Policy also applies to Cable and Wiring designs.

If you have a question about this service or would like to make a request to add, change, or terminate this service please contact TNS at (814) 865-1696 or submit your request through the Service Inquiry Form  Locked Content.

Lead times do not include projects that require coordination with OPP, non-PSU architects, and/or engineers, or other 3rd party contractors.
Inside Building
Lead times assume the following:
  1. Lead times BEGIN when all outlet locations have been identified and shown graphically on a plan.
  2. Adequate space exists within the serving Telecommunications Room for all required active and passive components and equipment.
Definitions
  • Jack - A single telecommunications RJ-45, coax or MT-RJ, ST or SC fiber connector.
  • Outlet - A telecommunications physical location consisting of a single or multiple jacks located on a single faceplate.
6 Outlet locations or less 3 Days
50 Jacks or less 3 Weeks
Over 50 Jacks 5 Weeks
Complete Building To be determined
Between Buildings (Inter Building wire/fiber)
Definitions

Segment - a single pole-to-pole span or a manhole-to-manhole duct bank section

Lead times assume the following:

  1. No Right-of-Way agreements are required.
  2. No pole attachment agreements are required.
  3. Project involves only University owned property
  4. Adequate pathways (either duct bank or aerial) exist. Lead times do not include design for construction of new pathways.
  5. Does not include copper telephone wiring. Lead times vary according to how far into the distribution system the design must address to find available pairs.
Short Runs (3 Segments or Less) 4 Weeks
Other Runs (more than 3 Segments) 6 Weeks
For more information call (814) 865-6580 or submit an inquiry through the Special Projects Design Request Form